6. EtherNet/IP Settings
13
*1. The original data type is defined as "SINT". In this document, it is defined as "BYTE" that can be
displayed in “ASCII” for readability when monitoring with the Watch Tab Page of Sysmac Studio.
■ Definition of Status Signal area access data types (struct
ure)
Data types for accessing the Status Signal area.
Note
Please refer to
Appendices A-2 EtherNet/IP Specifications
in the
Autofocus Multicode
Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication
Settings
(Cat. No. Z407) for a description of how to use each bit.
Name of data type
Data type
Code reader data
S_EIPInput103
STRUCT
---
INFO_BITS
BYTE
INFO BIT
RESERVED1
BYTE
Reserved for future use
RESERVED2
BYTE
Reserved for future use
RESERVED
3
BYTE
Reserved for future use
DEVICE_STATUS
Device_Status
Status Signal (32 bits)
FAULT CODE
DINT
Error code
COUNTERS
ARRAY[0..5]
OF DINT
Read Count Information
READ_CYCLE_
REPORT
ARRAY[0..3]
OF INT
Read Cycle Report
DECODE_CYCLE_
REPORT
ARRAY[0..3]
OF DINT
Decode Cycle Report
CODE_TYPE
DINT
Read Symbol Type
PIXELS_PER_
ELEMENT
REAL
Read Symbol PPE Size
DECODE_LENGTH
DINT
Decoded String Length
DECODE_DATA
ARRAY[0..435]
OF BYTE
*1
Decoded String
Name of data type
Data type
Code reader data
Device_Status
ARRAY[0.31]
OF BOOL
---
Run_Mode
BOOL
Run Mode
Trigger_Acknowledge BOOL
Accept trigger
Exposure_Done
BOOL
Exposure Done
Omitted
Output3_Status
BOOL
Output3 Status
Buffer_Overflow
BOOL
Buffer Overflow
Reserved
ARRAY
[0..9] OF
BOOL
Reserved for future use