7. EtherNet/IP Connection Procedure
40
7.3.7.
Transferring the Project Data
Place the Sysmac Studio online and transfer the connection settings and project data to the
controller.
When you transfer a user program, Configurations and Setup data, device
variables, or memory values for CX Units from the Sysmac Studio, the devices
and machines may operate unexpectedly regardless of the operating mode of
the CPU Unit.
Before transferring the project data, check the safety of the destination slaves.
1
Turn ON the power supply to
the controller, switching hub,
and code reader.
2
Select
Check All Programs
from the
Project
Menu.
3
The
Build
Tab Page is
displayed.
Confirm that
0
is shown for both
Errors
and
Warnings
.
4
Select
Rebuild Controller
from
the
Project
Menu.
5
A confirmation dialog box
appears. Confirm the
information and click the
Yes
Button.
6
In the
Build
Tab Page, confirm
that
0
is shown for both
Errors
and
Warnings
.
Содержание MicroHAWK V320-F