6. EtherNet/IP Settings
11
6. EtherNet/IP Settings
This section shows the specifications of the parameters, global variables, tag sets, and tag
data link table that you set in this document.
In subsequent sections, the code reader may also be referred to as “target device” depending
on the description.
6.1. Parameters
The parameters that you set in this document are shown below.
6.1.1.
EtherNet/IP Communication Settings
The parameters used for connecting the controller and the code reader via EtherNet/IP are as
follows.
* For the use cases in this document, setting the gateway is unnecessary because the devices
are connected within the same segment of the network.
Set the code reader’s gateway setting to any value. It must not be left blank.
6.1.2. About the Code Reader Assemblies
The code reader has six types of Input Assemblies and two types of Output Assemblies, and
one type can be selected for each.
The data structure changes based on the selected assembly.
Assembly Type
Assembly Name
Assembly Number
Input Assembly
Small Input Assembly
100
Input Assembly
Large Input Assembly
101
Input Assembly
MXL/SLC Input Assembly
102
Input Assembly
1 Decode Input Assembly
103
Input Assembly
4 Decode Input Assembly
104
Input Assembly
N Decode Input Assembly
105
Output Assembly
Output Assembly
197
Output Assembly
Output Assembly (Legacy)
198
For a detailed explanation of memory allocation and the data structure of each assembly, refer
to
Appendices A-2 EtherNet/IP Specifications
in the
Autofocus Multicode Reader MicroHAWK
V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings
(Cat. No.
Z407).
Parameter name
Controller
Code reader
Ethernet
---
Enabled
IP address
192.168.188.200
192.168.188.2
Subnet mask
255.255.0.0
255.255.0.0 (default)
Gateway
---
0.0.0.0 (default), any value
IP Address Mode
---
Fixed
EtherNet/IP
---
Enabled
KeepAlive
Enabled (default)
---