6. EtherNet/IP Settings
12
6.2. Data Types to Use for Tag Data Links
This section describes an example of using data types for the code reader’s tag data link data.
<Input and Output Assemblies>
• Input Assembly: 1 Decode Input Assembly (103)
• Output Assembly: Output Assembly (197)
6.2.1. Output Area
The Output Area is an area where you can send commands to the code reader, such as
trigger input commands and commands for registering Match strings.
■ Definition of Output Area access data types (structure)
Data types for accessing the Output Area.
Name of data type
Data type
Code reader data
S_EIPOutput197
STRUCT
---
COMMANDS
COMMAND Control signal (32 bits)
■ Definition of
control signal area access data types (structure)
Data types for accessing the control signal area.
6.2.2.
Input Area
The Input Area is an area where you can check the control status and output character strings
of the code reader, such as Accept Trigger confirmation and Read OK/NG results.
■ Definition of Input Area access data types (structure)
Data types for accessing the Input Area.
Name of data type
Data type
Code reader data
COMMAND
ARRAY[0..3
1] OF BOOL
---
Run_Mode
BOOL
Run Mode
Trigger
BOOL
Trigger
Enable_MatchCode
BOOL
Enable MatchCode
Omitted
Output_2
BOOL
Output 2
Output_3
BOOL
Output 3
Reserved
ARRAY[0..1
7] OF BOOL
Reserved for future use