6. EtherNet/IP Settings
15
■ EIPInput Structure
*1. Control Signal Assignment
Variable: EIPInput.Device_status Assignment
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
DataIs
Ready
Deco
ding
Trigger
Acknow
ledge
Run
Mode
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RunMode: ON when in Read Cycle
Trigger Acknowledge: ON when Output Assembly Trigger Bit is received
Decoding: ON while image is being processed
DataIsReady: ON when Data Output and Judgment are verified
Precautions for Correct Use
If the data size of the code reader's tag data link data is an odd number of bytes, declare it
as BYTE instead of BOOL.
Code reader data
Variable name
Data type
INFO BIT
EIPInput.INFO_BITS
BYTE
Reserved for future use EIPInput. RESERVED
1
BYTE
Reserved for future use EIPInput. RESERVED
2
BYTE
Reserved for future use EIPInput. RESERVED
3
BYTE
Status Signal (32 bits)
EIPInput.DEVICE_STATUS
*1
BOOL[32]
Error code
EIPInput. FAULT
DINT
Read Count Information EIPInput. COUNTERS
DINT[6]
Read Cycle Report
EIPInput.
READ_CYCLE_REPORT
INT[4]
Decode Cycle Report
EIPInput.
DECODE_CYCLE_REPORT
INT[4]
Read Symbol Type
EIPInput. CODE_TYPE
DINT
Read Symbol PPE
EIPInput.PIXELS_PER_ELEMENT REAL
Decoded String Length EIPInput. DECODE_LENGTH
DINT
Decoded String
EIPInput DecodeData
BYTE[436]