6. EtherNet/IP Settings
14
6.3. Global Variables
The controller treats the data in tag data links as global variables. The settings for global
variables are shown below.
The global variables below are set in the “project file”.
Variable
Network Publish
Data type
Application
EIPOutput
Out
S_EIPOutput197 For data links to the Output Area
EIPInput
In
S_EIPInput102 For data links to the Input Area
■ EIPOutput Structure
*1. Control Signal Assignment
Variable: EIPOutput.COMMAND Assignment
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
TRIG RUN_
MODE
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
TRIG: Execute Read Bit: When ON, Read is executed.
RUN MODE: When ON, Trigger can be accepted and Read Cycle is enabled.
Code reader data
Variable name
Data type
Control signal (32 bits) EIPOutput.COMMAND
*1
BOOL[32]