7. EtherNet/IP Connection Procedure
21
7
If the WebLink startup screen does not appear, it means that communications are not
established between the code reader and the PC. Please check the following.
• Does the code reader and the PC have a proper physical (cable) connection?
• Are the IP Addresses of the PC and code reader set correctly?
→ Refer to
step 4
for setting the IP address of the PC.
• Do a hardware reset of the code reader.
→ When turning ON the power supply, press and hold the
setup button on the code
reader body until its light turns on.
For other measures that can be taken, please refer to
When unable to access by WebLink
in
Q&A
in
Appendices
of the
MicroHAWK V320-F/V330-F/V420-F/V430-F Series Barcode
Reader User Manual
(Cat. No. Z432).
8
The WebLink screen appears.
9
Click on the
Setup
tab and, in
Read Cycle Sequence
, set
Cycle
to
Triggered
.
10
Click on the gear icon on the
upper right of the screen to
select
Advanced
.