Adjusting the Images That Were Taken
FQ2-S/CH User’s Manual
97
3
Ta
ki
ng Ima
ges
• RGB
• HSV
5
Press [OK].
6
Press [Back].
Parameter
Setting
Description
Filter settings
• Red filter (Default)
• Green filter
• Blue filter
• Cyan filter
• Magenta filter
• Yellow filter
• Brgt.F (brightness filter) (R+G+B)
• Brgt.F (brightness filter) (R+2G+B)
• Custom filter
These filters achieve the same effect as when
using the selected optical filter.
R
Range: 0.0001 to 9.9999
Default: 0.3000
These are the RGB gain settings for a custom
filter.
Increase the gain to increase the density of that
color component.
You can set the gains only if [Custom filter] is
selected in the filter settings.
G
Range: 0.0001 to 9.9999
Default: 0.5900
B
Range: 0.0001 to 9.9999
Default: 0.1100
Parameter
Setting
Description
Std. Hue
(standard hue)
Range: 0 to 359
Default: 0
Sets the standard hue for the HSV filter.
The density will decrease as the difference between
the hue and the standard hue increases.
Hue range
Range: 10 to 180
Default: 90
Sets the hue range for the HSV filter.
The hue range centered on the standard hue is
divided into 255 levels to find the difference in the
hue. Hues that are outside the hue range will have a
density of 0.
Chroma
(saturation)
Range: 0 to 255 (Default)
Set the upper and lower limit values for the chroma
(saturation).
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......