Inspecting with the Sensitive Search Inspection Item
266
FQ2-S/CH User’s Manual
Unstable Search Results
Inclined Measurement Objects
Adjust the [Angle range] parameter to increase the range in which a search is made for the model.
The Search inspection item judges whether an image is OK or NG according to the correlation with a
previously registered image pattern.
For this reason, if the object is at an angle, the correlation is reduced and the image may be judged as NG.
To achieve an OK judgment for the same image pattern even when the object is at an angle, the rotation range
must be widened.
[Inspect]
−
[Inspection]
−
[Sensitive Search]
−
[Modify]
−
[Details] Tab Page
−
[Model parameter]
1
Set [Rotation] to [Yes].
2
Press [Angle range] and set the following range.
Correlation Is Inconsistent Due to Low Contrast
Adjust the brightness to improve the contrast of the mark.
Adjusting the Brightness: p. 77
Correlation Is Inconsistent Due to Variations in the Measurement Object
Inconsistent portions can be masked so that they are omitted from matching.
Model masking: p. 226
Parameter
Setting
Description
Angle range
Range:
−
180 to 180
Default: Lower:
−
180
Upper: 180
A search is performed within the set angle range.
The larger the angle range, the longer the processing
time.
If you change the angle range, perform teaching again.
Important
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......