Wiring
54
FQ2-S/CH User’s Manual
2-5 Wiring
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
Wiring the Sensor
Connect the I/O Cable to the I/O Cable connector located at the bottom of the Sensor.
• Cut off lines that are not required so that they do not come into contact the other signal lines.
• Do not allow the load current to exceed 50 mA.
The output circuit may be damaged if the load current exceeds 50 mA.
Classification
Signal
Application
Power supply
Power supply (24 V) These terminals are for the external power supply (24 V).
Wire the power supply separately from other devices. If the wiring for other
devices is placed together or in the same duct as the wiring for the Sensor,
the influences of electromagnetic induction may cause the Sensor to mal-
function or may damage it.
GND
Inputs
TRIG
This terminal is the trigger signal input.
IN0 to IN5
These are the command input terminals.
Outputs
OUT0 (OR)
By Default, this is the OR output signal (overall judgment).
The assignment can be changed to RUN, READY, an individual judgment
signal from OR0 to OR31, the STGOUT (strobe trigger output), or an
expression judgment from 0 to 31.
OUT1 (BUSY)
By Default, this is the BUSY output signal.
The assignment can be changed to RUN, READY, an individual judgment
signal from OR0 to OR31, the STGOUT (strobe trigger output), or an
expression judgment from 0 to 31.
OUT2 (ERROR)
By Default, this is the ERROR output signal.
The assignment can be changed to RUN, READY, an individual judgment
signal from OR0 to OR31, the STGOUT (strobe trigger output), or an
expression judgment from 0 to 31.
For the IN/OUT type of the Sensor and Sensor Data Unit, use the same IN/OUT type (NPN/PNP).
GND
OUT0 (OR)
OUT1 (BUSY)
OUT2 (ERROR)
IN0
TRIG
IN1
IN2
IN3
IN4
IN5
Yellow
Purple
White
Red
Green
FQ-WD0
@@
I/O Cable
Gray
Pink
Light blue
Orange
Black
Blue
Power supply
Brown
FQ2-S
@@@@@@
/FQ2-CH1
@@@@@
-M
(Sensors with Built-in Lighting or Sensors with
C-mounts)
Important
Important
Note
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......