External Reference Parameters
526
FQ2-S/CH User’s Manual
Sensitive Search (FQ2-S1/S2/S3 series or FQ2-S4 series only)
700
Display
settings
Correlation display
Set / Get 0: Display
1: Do not display
0
---
---
701
Position X display
Set / Get 0: Display
1: Do not display
0
---
---
702
Position Y display
Set / Get 0: Display
1: Do not display
0
---
---
703
Measurement angle
display
Set / Get 0: Display
1: Do not display
0
---
---
704
Count display
Set / Get 0: Display
1: Do not display
0
---
---
800
Position X display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0
---
---
801
Position Y display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0
---
---
802
Measured angle dis-
play pattern
Set / Get 0: Absolute value
1: Relative value
0
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not mea-
sured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed
error,
−
14: Figure not registered error,
−
15: Out of range error
−
2
JG
Logged data
5
Correlation
Get only
0 to 100
0
CR
Logged data
6
Deviation
Get only
Color Camera:
0.000 to 219.9705
Monochrome Camera:
0.000 to 127.000
0
DV
Logged data
7
Measurement position
X (search center posi-
tion)
Get only
−
99,999.9999 to 99,999.9999
0
X
Logged data
8
Measurement position
Y (search center posi-
tion)
Get only
−
99,999.9999 to 99,999.9999
0
Y
Logged data
9
Angle
Get only
−
180 to 180
0
TH
Logged data
10
Mea-
sure-
ment
result
Detection X
Get only
−
99,999.9999 to 99,999.9999
0
RX
Logged data
11
Detection Y
Get only
−
99,999.9999 to 99,999.9999
0
RY
Logged data
12
Reference position X
Get only
−
99,999.9999 to 99,999.9999
0
SX
Logged data
13
Reference position Y
Get only
−
99,999.9999 to 99,999.9999
0
SY
Logged data
14
Reference angle
Get only
−
180 to 180
0
ST
Logged data
15
NG sub-region
Get only
0 to 100
0
CT
Logged data
16
Sub-region number
Get only
0 to 99
0
AN
Logged data
17
Sub-region number (X)
Get only
0 to 9
0
ANX
Logged data
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...