Inspecting with the Search Inspection Item
FQ2-S/CH User’s Manual
229
4
Setting Up Inspect
ions
4-18 Calculations and Judgments Using Inspection Item Data
Measurement Data That Can Be Logged
The following values can be logged as measurement data.
*When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data
Errors
Errors in Teaching
A teaching error message will appear if the contrast of the image within the model registration region is too low.
Select a region with a larger contrast between light and dark areas compared to the region that was registered
as the model and re-register it as the model.
SX
Reference X
−
99,999.9999 to 99,999.9999
This is the X coordinate of the position
where the model was registered.
SY
Reference Y
−
99,999.9999 to 99,999.9999
This is the Y coordinate of the position
where the model was registered.
ST
Reference angle
−
180 to 180
This is the angle when the model was
registered.
RX
Detection coordinate X
−
99,999.9999 to 99,999.9999
−
99,999.9999 to 99,999.9999
This is the X coordinate of the detection
point when the model was registered.
RY
Detection coordinate Y
−
99,999.9999 to 99,999.9999
This is the Y coordinate of the detection
point when the model was registered.
C
Count
0 to 32
This is the number of models found.
Parameter
Range of value
Description
Judgement
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the measurement judgment results.
Correlation
0 to 100
This is the measured correlation.
Position X
-99999.9999 to 99999.9999
This is the measurement position X.
Position Y
-99999.9999 to 99999.9999
This is the measurement position Y.
Angle
−
180 to 180
This is the measurement angle.
Count
0 to 32
This is the number of models found.
Expression
text string
Data name
Description
Data range
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......