Error Histories
432
FQ2-S/CH User’s Manual
8-1 Error Histories
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
Error histories are stored with the PC Tool and in the Sensor and in the Touch Finder.
Up to 100 errors will be stored in the error history in the Sensor or Touch Finder.
Errors Stored in the Error History
Note:
If an error that is indicated by this icon occurs, the ERROR operation indicator will light and the ERROR signal will turn ON.
Error code
Cause
Points to check
Measures to perform
TRIG Input Error
(Error code (hex): 01040302)
A TRIG signal was input when
the BUSY signal for Sensor
measurement was ON.
• Check the program in the PLC
or other host to see if an inter-
lock or similar measure has
been implemented.
• If a relay or other device with
contacts is being used as the
input device, see if chattering
has occurred.
• Program interlocks to control
the TRIG so that they do not
turn ON while the BUSY signal
is ON.
• Switch from a device with con-
tacts (e.g., relay) to a device
without contacts (e.g., SSR or
PLC transistor output).
IN Input Error
(Error code (hex): 11020900)
A parallel command was input
while the BUSY signal was ON.
Is an interlock or other
countermeasure provided, e.g., in
a ladder program in the PLC?
Is the wiring appropriate?
• Interlock so that a parallel
command is not input when the
BUSY signal is ON in a ladder
or otherwise.
• Malfunctioning will occur if the
power ground level of the FQ-
S is different from the power
ground level of the connected
IO device. Short the two power
GNDs together.
Scene Data Error
(Error code (hex): 01030800)
T
he scene data to switch to is
corrupted.
---
The scene data to be switched
to is corrupted.
Reset the scene data from the
beginning.
Model Error
(Error code (hex): 01050405
or 01050500)
A model was re-registered with
an image with low contrast.
Check the image to see if the
contrast is too low to register the
model.
Increase the image contrast and
try again to register the model.
Logging Error
(Error code (hex): 02160702
or 02160703)
Some data was not saved when
logging data to files on an SD
card.
Check to see if the BUSY output
parameter is set to
Measurement
.
Set a sufficiently long measure-
ment interval or set the BUSY
output condition to [Data logging]
or [Image logging].
Communication error
(Error code (hex): 01010100)
After EtherNet/IP communica-
tion or PROFINET communica-
tion was established, normal
communication could not be
performed.
Check to see if communications
were cut off with the data link
partner device and to see if a
cable is broken.
Check the cable connection to the
data link partner device.
EtherNet/IP communica-
tions error
(Error code (hex): 01010101)
A timeout occurred in process-
ing to output the measurement
results via EtherNet/IP, PROF-
INET.
Make sure that handshake pro-
cessing is being performed by the
master. Also, make sure that the
measurement interval is long
enough.
Check the measurement interval
and handshake processing.
Change the timeout time so that it
is suitable for the ladder program
processing time.
Output buffer error
(Error code (hex): 01010701)
An output data buffer overflow
occurred during output process-
ing of measurement results for
PLC Link or EtherNet/IP, PROF-
INET.
• Check the measurement inter-
val to see if it is long enough.
• Make sure that handshake
processing is being performed
by the master.
Check the measurement interval
and handshake processing.
SD card output error
(Error code (hex): 01050300)
A write to the SD card failed.
An attempt was made to save
more data than the available
space on the SD card.
• Check to see if the SD card is
locked. Check to see if there is
sufficient space available on
the SD card.
• Verify that the SD card's format
is FAT/ FAT32.
• Make the SD card’s format
FAT or FAT32 using a PC.
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......