External Reference Parameters
486
FQ2-S/CH User’s Manual
Shape Search Position Compensation
External
reference
number
Category
Data name
Set / Get
Data range
Default
Expression
text string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
JG
Logged data
5
Scroll X
Get only
−
99999.9999 to 99999.9999
0
DX
Logged data
6
Scroll Y
Get only
−
99999.9999 to 99999.9999
0
DY
Logged data
7
Scroll
θ
Get only
−
180 to 180
0
DT
Logged data
8
Position X
Get only
−
99999.9999 to 99999.9999
0
X
Logged data
9
Position Y
Get only
−
99999.9999 to 99999.9999
0
Y
Logged data
10
Angle
Get only
−
180 to 180
0
TH
Logged data
11
Reference X
Get only
0 to 9,999
0
SX
Logged data
12
Reference Y
Get only
0 to 9,999
0
SY
Logged data
13
Reference angle
Get only
−
180 to 180
0
ST
Logged data
14
Correlation
Get only
0 to 100
0
CR
Logged data
103
Output
parame-
ter
Reflect
Set / Get
0: Yes
1: No
0
---
---
120
Mea-
sure-
ment
condi-
tions
Position compensa-
tion precision
Set / Get
0: None
1: Bilinear
0
---
---
121
Setting method
Set / Get
0: Cancel position compensation
1: Position compensation based on
internal search
1
---
---
122
Position compensa-
tion image
Set / Get
0: Camera image,
1: Previous image
1
---
---
123
Model
region
Rotation
Set / Get
0: No rotation
1: Rotation
1
---
---
124
Reference X
Set / Get
0 to 9,999
0
---
---
125
Reference Y
Set / Get
0 to 9,999
0
---
---
126
Reference angle
Set / Get
−
180 to 180
0
---
---
140
Rotation angle upper
limit
Set / Get
−
180 to 180
180
---
---
141
Rotation angle lower
limit
Set / Get
−
180 to 180
−
180
---
---
149
Mea-
sure-
ment
condition
Candidate level
Set / Get
0 to 100
70
---
---
150
Detec-
tion point
coordi-
nate
Detection point X
Set / Get
0 to 9,999
0
---
---
151
Detection point Y
Set / Get
0 to 9,999
0
---
---
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......