*1 Measurement ID is calculated -1 from measurement counts. This ID is counted from zero at launch of FQ2.
The recent log data will be cleared if the scene is changed.
Changing the Format for Saving Measurement Data
The output CSV file format can be changed according to the external device.
Changing the Format for Saving Measurement Data: p. 399
Displaying Image Data
• Images Saved in Internal Sensor Memory
(Setup
Mode)
−
−
[Log]
• Image Files in an SD Card
(Setup
Mode)
−
−
[Logging image file] or [Camera image file]
Displaying a Saved Image: p. 382
Item
Format
Content
1)
Index
―
Index
2)
Measurement ID
―
Measurement ID Information
*1
3)
Scene No.
―
Scene Number
4)
Judge
―
Overall judgment result
0: OK
-1: NF
-2: NC (means unmeasured)
5)
Inspection item
region
Inspection item No., Measurement
item, Inspection point
Example 1
When Search is executed with
inspection item No,0, the second
correlation value is I0, CR1.
Example 2
Judgment result in OCR of inspec-
tion item No,1 is I1, JG
Outputs a data selected as a logging item in [Measurement data] of
[Logging setting].
When multiple results in Search are detected, outputs the maximum
data that set in [Measurement data].
6)
A
rithmetic
expression
region
Example
Arithmetic expression judgment
registered the fist:
Z0.J00,Z0.D00?FQ2-S1?
Zn.J**, Zn.D**
Example
The fourth registered arithmetic expression is Z0.J04.Z0.D04 when
you use FQ2-S1.
• The saved recent measurement data cannot be loaded back into the Sensor and displayed on a trend monitor or histo-
gram.
• The data and time are not recorded with the measurement data.
The file name is created from the time when the file is saved. It does not indicate when the measurement was made.
Note
Important
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......