Adjusting the Timing of Taking Images
88
FQ2-S/CH User’s Manual
[Image]
−
[Trigger setup]
−
[Trigger delay]
r
1
A TRIG signal is input.
Images are input continuously.
2
Select the image with the measurement object
in the center using
and
.
3
Press the image.
4
Press [OK].
Setting item
Setting value
Description
Trigger delay
Range: 0 to 163ms
Default: 0
Adjusts the time for opening the camera shutter after Trigger
conditions are established.
Only valid for external triggers.
Delay time = (Setting value) + 150
μ
s
The delay time can be set using the adjustment bar or by directly entering a value.
Note
Directly input the delay time.
Or
Move the bar to the left or right.