Section 6-3
$)$
Other machinery (that is not visible) now automatically removes the object and the
proximity switch becomes inactive. At CV1 the drill-motor turns OFF and at CV0
the feed-motor is switched to move slowly until it reaches the limit switch and is
switched OFF (via the ladder program). At this moment a new object is placed in
position again. At this moment the feed-motor stays switched OFF for as long as
the proximity switch has detected a new object, initiating the whole cycle again.
The limit switch is connected to Digital Input I0 which is assigned function 05 (i.e.
Reset Rising Edge). Activation of the limit switch when the drill-motor is in the
home position causes Counter 1 to be reset and the feed-motor to be switched to
its initial state (slow/forward). An Output Reset Pattern (m+61, m+62) has been
defined to switch the feed-motor to its initial state.
DM-configuration
The Machine Number of the High-speed Counter Unit is 0. The High-speed Coun-
ter is allocated 40 CIO-words starting from CIO 2000 (n = CIO 2000 + 0 x 10) and
400 DM-words starting from D 20000 (m = D 20000 + 0 x 100). The Comparison
Data of Counter 1 is stored in EM starting from EM 1500. To configure the Unit the
following DM-settings must be made.
Comparison Data Counter 1
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
:DM-word
(Thehyphen
“-“ indicates that thecontentsof the corresponding digit is
irrelevant
and thevaluedoes notcare)
General DM-Settings:
D 20000(= m)
- - - 1
Comparis
on Mode(=1)
D 20017(= m+17)
0 1 0 5
Counter
1 (=01),Digital Input I0 Function05(=05
(BCD)
)
Counter 1 DM-settings:
D 20030(= m+30)
- - - 1
Linear
Counter (=1)
D 20057(= m+57)
0 0 0 F
D 20058(= m+58)
0 0 0 0
Enable
CV0,CV1,CV2 and CV3
D 20061(= m+61)
0 0 0 3
D 20062(= m+62)
0 0 0 0
Output
ResetPattern Counter 1: Reset Digital Outputs O0and O1(i.e. prepare
feed-mot
or M1 for initial state:slow speed/ forward direction)
D 20064(= m+64)
- - 0 4
Total number
of Comparison Values is 4 (=04
(BCD)
)
D 20065(= m+65)
- - - 0
Memory Are
aisEM (=0)
D 20066(= m+66)
1 5 0 0
D 20067(= m+67)
0 0 0 0
IndirectAddres
s is EM 1500 (=00001500
(BCD)
)
1 3 8 8
0 0 0 0
0 0 0 1
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 1
0 0 0 0
Comparison Data Counter 1
CV 0 settings of Counter 1 (in EM)
EM 01500
EM 01501
EM 01502
EM 01503
EM 01504
EM 01505
EM 01506
EM 01507
EM 01508
EM 01509
Comparison Value 0 is 5000 (=00001388
H
)
+Set Pattern: Set Digital Output O0 (i.e. change speed of feed-motor M1
from slow (=0) to fast (=1) in the positive (=+) counting direction
+Reset Pattern: no outputs are rest at the crossing of CV0 in the positive
counting direction
-Set Pattern: no outputs are set at the crossing of CV0 in the negative
counting direction
-Reset Pattern: Reset Digital Output O0 (i.e. change speed of feed-motor M1
from fast (=1) to slow (=0) in the negative counting (=-) direction
W902-E2-03.book Seite 161 Donnerstag, 7. Oktober 2004 2:06 14
Содержание CS1W-CT021
Страница 1: ...OPERATION MANUAL High speed Counter Units CS1W CT021 CS1W CT041 Cat No W902 E2 03...
Страница 3: ...W902 E2 03 book Seite iv Donnerstag 7 Oktober 2004 2 06 14...
Страница 5: ...W902 E2 03 book Seite vi Donnerstag 7 Oktober 2004 2 06 14...
Страница 39: ...W902 E2 03 book Seite 24 Donnerstag 7 Oktober 2004 2 06 14...
Страница 59: ...A 2 Section 2 3 W902 E2 03 book Seite 44 Donnerstag 7 Oktober 2004 2 06 14...
Страница 155: ...4 Section 4 6 W902 E2 03 book Seite 140 Donnerstag 7 Oktober 2004 2 06 14...
Страница 199: ...G W902 E2 03 book Seite 184 Donnerstag 7 Oktober 2004 2 06 14...