F"")"-$).#+
Section 5-2
$'+
5-2-4
Preset error
A Preset error is generated if a Circular or Linear Counter is preset with an invalid
Preset Value (refer to 3-4
for more information about pre-
setting). The Preset Value is invalid if it is outside the counting range of the Circu-
lar or Linear Counter.
Clearing Preset error
A Preset error can be cleared by resetting or by presetting the Counter that gen-
erated a Preset error, with a valid Preset Value. To reset a Counter refer to 3-6
. To preset a Counter refer to 3-4
5-2-5
Interrupt FIFO full error
Every interrupt that you want to use is assigned to an external interrupt task
number (0-255). This number corresponds with the external interrupt task in the
CS1-CPU that is to be executed when the assigned interrupt is activated (refer to
4-6
Multiple interrupts, generated by the Digital Inputs and/or the Outputs, will be
queued in FIFO-order inside the High-speed Counter Unit, for as long as the cur-
rent active interrupt is not executed. If the FIFO-buffer is full the Unit will report an
error to the CS1-CPU. All interrupts generated by the Unit, after the “Interrupt
FIFO full” error has occurred will be ignored and will not generate additional errors.
Error Code 2 contains the external interrupt task number of the corresponding
interrupt that was excluded from the full FIFO-queue.
Clearing Interrupt FIFO
error
If the speed with which the High-speed Counter Unit generates interrupts is higher
than the speed with which the CS1-CPU executes the interrupts, the FIFO-buffer
inside the Unit runs full and the “Interrupt FIFO full” error is generated. The error
can be cleared by issuing the IOWR-instruction with the Error Clear (“EC”) com-
mand (refer to 4-5-3-5
for details).
The error indicates that the load of interrupts on the CS1-CPU is too high. Clearing
the error as mentioned before most probably needs additional measures to be
taken in order to prevent this error from happening in the future:
•
Mask one or more interrupts of the Unit, which caused the error.
•
Mask one or more interrupts of other Units in the system, which are generating
interrupts as well.
•
Reduce the execution time of the assigned External Interrupt Tasks.
Error Code 1
Error Code 2
Error
Description
0470
Counter No.
Invalid Preset Value
The Linear Counter with the
Counter No.
as
reported in Error Code 2 is preset with an
invalid Preset Value.
Error Code 1
Error Code 2
Error
Description
0480
External Interrupt
Task No.
Interrupt-FIFO full
The interrupt-FIFO inside the High-speed
Counter Unit is full and the interrupt assigned
to
External Interrupt Task
could not be
executed.
W902-E2-03.book Seite 148 Donnerstag, 7. Oktober 2004 2:06 14
Содержание CS1W-CT021
Страница 1: ...OPERATION MANUAL High speed Counter Units CS1W CT021 CS1W CT041 Cat No W902 E2 03...
Страница 3: ...W902 E2 03 book Seite iv Donnerstag 7 Oktober 2004 2 06 14...
Страница 5: ...W902 E2 03 book Seite vi Donnerstag 7 Oktober 2004 2 06 14...
Страница 39: ...W902 E2 03 book Seite 24 Donnerstag 7 Oktober 2004 2 06 14...
Страница 59: ...A 2 Section 2 3 W902 E2 03 book Seite 44 Donnerstag 7 Oktober 2004 2 06 14...
Страница 155: ...4 Section 4 6 W902 E2 03 book Seite 140 Donnerstag 7 Oktober 2004 2 06 14...
Страница 199: ...G W902 E2 03 book Seite 184 Donnerstag 7 Oktober 2004 2 06 14...