9 References
9-1 Specifications
BL50T/BL75T/BL100T
79
9
Model
BL50T
BL75T
BL100T
Enviro
nment
Usage environment
temperature/humidity
0 to 40 degrees Celsius/25 to 85% RH (no condensation)
Storage temperature
-15 to 50 degrees Celsius/10 to 90% RH (no condensation)
Safety standards/RoHS
compliance
UL1778/RoHS compatible/CE/UN38.3
Emission AC power
supply radiated
electromagnetic field
emissions
VCCI Class A
Internal power
consumption
Without load Normal
operation/maximum
With rated load Normal
operation/maximum
(For conversion into
kilojoule/hour [kJ/h], use
"internal power consumption
(W) x 3.6" for calculation.)
15W/80W
30W/140W
15W/100W
45W/180W
15W/120W
60W/250W (*5)
Noise
50dB
Dimensions (WxDxH)
140mm × 330mm ×
167mm
140mm × 330mm
× 167mm
155mm × 330mm
× 167mm
Weight of unit
Approximately
5.2kg
Approximately
5.8kg
Approximately
6.4kg
*1 100V mode, minimum input voltage: 70V, load: 90%
*2 When standard sensitivity is set
*3 When low voltage sensitivity is set
*4 When high voltage sensitivity is set
*5 Rated load/rated input voltage
Содержание BL100T
Страница 17: ...1 Preparation 1 2 Check the accessories BL50T BL75T BL100T 17...
Страница 21: ...1 Preparation 1 5 I O circuit block diagram BL50T BL75T BL100T 21 1 5 I O circuit block diagram...
Страница 23: ...2 Installation and connection 2 1 Install BL50T BL75T BL100T 23 2 Do not install in any of the following ways...
Страница 73: ...7 How to use optional cards 7 3 SNMP Web card BL50T BL75T BL100T 73 7 7 3 SNMP Web card LAN 10 100...
Страница 80: ...9 References 9 2 Dimensions BL50T BL75T BL100T 80 9 2 Dimensions Unit mm Tolerance 2mm BL50T BL75T BL100T...