59
Electromagnetic Compliance
OML Remote
Manufacturer’s declaration of electromagnetic immunity continued
The OML Remote is intended for use in an electromagnetic environment
in which radiated RF disturbances are controlled. The customer or the
user of the OML Remote can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and the OML Remote as
recommended below, according to the maximum output power of the
communications equipment.
Rated maximum
output power of
transmitter (W)
Separation distance according to frequency of
transmitter (m)
150 kHz to
80 MHz
d = 1.2 * √P
80 MHz to
800 MHz
d = 1.2 * √P
800MHz to
2.5GHz
d = 2.3 * √P
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.20
1.20
2.30
10
3.79
3.79
7.27
100
12.0
12.0
23.0
For transmitters rated at a maximum output power not listed above, the recommended
separation distance in metres (m) can be estimated using the equation applicable to the
frequency of the transmitter where P is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range
applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.