Troubleshooting
Symptom
Probable cause
Item to check
Countermeasures
Intervention
mode
One or both sides
do not heat up
Fuse or resistance
break
Check the
heating fuses.
Check the
integrity of the
resistances.
Checking the
components with the
wiring diagram
Maintenance
technician.
Machine in
MANUAL
mode
The clamps heat
up but the
temperature is
not detected by
the system.
Thermocouple
connection or
failure
Check the
integrity of the
thermocouple.
Check the
connections of
the
thermocouple
Checking the
components with the
wiring diagram
Maintenance
technician.
Machine in
MANUAL
mode
The movement of
the blades is
incorrect
The sliding
columns of the
cylinders are not
greased
Sliding
columns of
cylinders
Check the condition
and, if necessary,
grease the columns of
the cylinders
Maintenance
technician.
Machine in
MANUAL
mode