94MS36 Rev. F2 S/W Ver 2.06
1-3
Electrical specifications and connections
Earth
Ground
L1
L2
L1 L2
L3
Figure A
380 / 415V~ 50Hz Connection
Wye: 3 Wires + N Ground
Terminal Block
N
380 / 415V~
OLITE
Power Supply
Blowers
Vacuum
Pumps
Electronics
Drives
Etc.
L3
N
Earth
Ground
L1
L2
L1 L2
L3
Figure B
208/240V~ 50Hz Connection
DELTA: 3 Wires + Ground
Terminal Block
N
208V~
OLITE
Power Supply #1
Blowers
Vacuum
Pumps
Electronics
Drives
Etc.
L3
208V~
OLITE
Power
Supply #1
Earth
Ground
L1
L2
L1 L2 L3
Figure C
480V~ 60Hz Connection
DELTA: 3 Wires + Ground
Terminal Block
480V~
OLITE
Power Supply #1
Blowers
Vacuum Pumps
Electronics
Drives, Etc.
L3
X1 X2 X3
480V~
OLITE
Power
Supply #2
X1
X2
X3
X4
H1
H2
H3
H4
L1 L2 L3
Blowers
Vacuum Pumps
Electronics
Drives, Etc.
X1 X2 X3
X1
X2
X3
X4
H1
H2
H3
H4
480V~ OLITE
Power Supply #1
Earth
Ground
L1
L2
Figure D
480V~ 60Hz Connection
Single Phase: 2 Wires + Ground
Terminal Block
480V~ OLITE
Power Supply #2
Содержание Accuprint AP30-5000
Страница 1: ...P P AP30 5000 AP30 8000 High Resolution Printer Service Manual 94MS36 Rev F2 S W Ver 2 06 O ...
Страница 70: ...11 4 94MS36 Rev F2 S W Ver 2 06 ...
Страница 72: ...12 2 94MS36 Rev F2 S W Ver 2 06 ...
Страница 136: ...16 10 94MS36 Rev F2 S W Ver 2 06 ...
Страница 138: ...O Corporation 17112 Armstrong Avenue Irvine Ca U S A 92614 U S A 949 399 6500 Fax 949 399 6501 ...