94MS36 Rev. F2 S/W Ver 2.06
8-3
Work Lights
Note:
The work lights are controlled by a rocker switch on the underside
of the right front corner of the nose. If the work lights are not
turning on check the rocker switch and power to the switch. The
work lights receive their power from the autoformer in the nose
section
•
To change the lamps the trays must first be moved to the center position,
this is done by:
•
Press and hold the
S
button.
•
Press the
G
button.
•
Release both buttons when trays start moving.
•
Just before the trays reach the center turn the power off.
•
Lift the diffusion cover off of the light assembly.
•
Twist the lamp to disengage it from the socket and remove it.
•
Install in reverse order.
Nose Fans
Note:
The nose fans are controlled by a rocker switch on the underside
of the right front corner of the nose. If the nose fans are not turning
on check the rocker switch and power to the switch.
•
Remove the nose (see section Removing the Nose).
•
Disconnect the power leads to the blower(s).
•
Remove the blower(s).
•
Install in reverse order.
Cleaning or Replacing Nose Filters
•
Slide the filters toward the front of the unit and out of the brackets.
•
Clean metal filters with water or environmentally safe solvent.