94MS36 Rev. F2 S/W Ver 2.06
4-3
Input Diagnostics
•
Switch Check
The switch check can be done while in the Select mode.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1
,
2
,
3
, then
4
in sequence. The Vacuum window will read
[SEL_]
. This places you in select mode.
•
Press the
6
key. The Exposure window on the integrator will show
various numbers as the switches or keys are closed.
Examples:
With the upper frame moved in, the side access door
switches closed, and the
G
key pressed on the nose section,
the lower integrator display should read
[0165]
. With the lower
frame in, the display should read
[0172]
.
G
DOOR
FRAME SWITCH
FRAME
NUMBER DISPLAYED
128
+32
+4
+1
=
[0165]
(Upper Frame In)
128
+32
+4
+8
=
[0172]
(Lower Frame In)
•
Switch Table
Switch Value
Function
1
Upper frame in (labeled "frame")
4
Frame switch
8
Lower frame in (labeled "frame")
16
S
key, nose section
32
Door/emergency
z
switch
128
G
key, nose section
Typical values that you will see when all switches are good.
•
Upper tray in, Frame switch closed, Door and Emergency switches closed.
[0037]
The bottom display should read
[0037]
.
[0165]
When the
G
button is pushed the value should change to
[0165]
.
[0053]
When the
S
button is pushed the value should change to
[0053]
.
Содержание Accuprint AP30-5000
Страница 1: ...P P AP30 5000 AP30 8000 High Resolution Printer Service Manual 94MS36 Rev F2 S W Ver 2 06 O ...
Страница 70: ...11 4 94MS36 Rev F2 S W Ver 2 06 ...
Страница 72: ...12 2 94MS36 Rev F2 S W Ver 2 06 ...
Страница 136: ...16 10 94MS36 Rev F2 S W Ver 2 06 ...
Страница 138: ...O Corporation 17112 Armstrong Avenue Irvine Ca U S A 92614 U S A 949 399 6500 Fax 949 399 6501 ...