94MS36 Rev. F2 S/W Ver 2.06
4-1
4.
Diagnostics
Output Diagnostics
One of the many advancements OLEC has introduced to the field is the
ability of its equipment to run a self-diagnostic check. All computer-
activated functions and all internal and external switches can be checked
out on the integrator display by using the numerical keypad.
Output Functions Check
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1
,
2
,
3
, then
4
in sequence. The Vacuum window will read
[SEL_]
. This places you in select mode.
•
Press the
6
key to enter the Diagnostics mode. The number in the
Vacuum window will be the sum of all values for peripherals that are
turned On.
[o000]
Press the
9
key to reset the Diagnostics mode. This turns Off all
peripherals. Therefore the Vacuum window will indicate
[o000]
.
•
Refer to the Functions Table.
•
Press the number key to actuate the desired function. The numerical value
shown in the table should appear in the Vacuum window.
•
Press the function key number again to turn off the function. Press the
9
key to turn off all functions.
•
Press the
0
key twice to return to normal operation.
Содержание Accuprint AP30-5000
Страница 1: ...P P AP30 5000 AP30 8000 High Resolution Printer Service Manual 94MS36 Rev F2 S W Ver 2 06 O ...
Страница 70: ...11 4 94MS36 Rev F2 S W Ver 2 06 ...
Страница 72: ...12 2 94MS36 Rev F2 S W Ver 2 06 ...
Страница 136: ...16 10 94MS36 Rev F2 S W Ver 2 06 ...
Страница 138: ...O Corporation 17112 Armstrong Avenue Irvine Ca U S A 92614 U S A 949 399 6500 Fax 949 399 6501 ...