3-8
94MS36 Rev. F2 S/W Ver 2.06
Tray Mode
!
C
The default tray speed is set at the factory to 5 seconds. OLEC does not
recommend changing this setting without consulting the
OLEC factory. Damage to the transport can occur.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[trAY]
Press the
e
key until
[trAY]
appears in the Exposure window.
•
Press the
V
key once. The Vacuum window will read
[----]
and the
Exposure window will read
[codE]
. If lock mode was turned ON, enter
your code now, then press the
V
key, (If the lock code has never been
changed
section 4.3
, the default code is 000).
•
Enter the time you wish to have the tray speed set for. For example, for a
5.0 second travel time, press
5
,
0
and then press the
V
key again the
Memory window and Exposure window will return to normal brightness.
•
Press the
0
key twice to exit this mode.
Type Mode
!
C
The type has been set at the factory and should not be changed.
Proper operation of the unit will be affected if changed.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[tYPE]
Press the
e
key until
[tYPE]
appears in the exposure window. This places
you in the System Type option.
•
Press the
V
key once. The Vacuum window will read
[----]
and the
Exposure window will read
[codE]
. If lock mode was turned ON, enter
your code now, then press the
V
key, (If the lock code has never been
changed, the default code is 000).
[AP30]
Press the V key to cycle the Vacuum window to read [AP30]. This setting
applies to both the AP30 5kW and AP30 8kW, air conditioned and closed
loop models.
•
Press the
0
key twice to exit this mode.
Содержание Accuprint AP30-5000
Страница 1: ...P P AP30 5000 AP30 8000 High Resolution Printer Service Manual 94MS36 Rev F2 S W Ver 2 06 O ...
Страница 70: ...11 4 94MS36 Rev F2 S W Ver 2 06 ...
Страница 72: ...12 2 94MS36 Rev F2 S W Ver 2 06 ...
Страница 136: ...16 10 94MS36 Rev F2 S W Ver 2 06 ...
Страница 138: ...O Corporation 17112 Armstrong Avenue Irvine Ca U S A 92614 U S A 949 399 6500 Fax 949 399 6501 ...