3-4
94MS36 Rev. F2 S/W Ver 2.06
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
9
key five (5) times.
•
Press the
0
key once to exit this mode.
Two Value Exposure Mode
Note:
The two value mode enables the operator to run a different job or
resist on each frame. With this feature turned ON, a value entered
in the Vacuum window becomes an exposure value. For instance,
if you enter 800 in the Vacuum window and 450 in the Exposure
window, during an exposure both surfaces on the upper frame
will receive 800 mj while both surfaces on the lower frame will
receive 450 mj. To activate this option:
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[2UAL]
Press and release the
e
key until
[2UAL]
is displayed in the Exposure
window.
•
Press the
V
key to cycle mode ON or OFF.
•
Press the
0
key twice to exit this mode.
Split Exposure Mode
The split exposure mode works in conjunction with the previously
mentioned two value mode. It enables the user to select separate exposure
values for the upper and lower surfaces of each frame, in case different
exposures are required for each surface of the panel. An exposure can be
entered in the center display which will be used on the top surface of
each frame and a separate exposure value can be entered in the lower
display which will be used on the bottom surface of each frame.
Note
: The two value mode MUST be selected ON for the split exposure
mode to function.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
Содержание Accuprint AP30-5000
Страница 1: ...P P AP30 5000 AP30 8000 High Resolution Printer Service Manual 94MS36 Rev F2 S W Ver 2 06 O ...
Страница 70: ...11 4 94MS36 Rev F2 S W Ver 2 06 ...
Страница 72: ...12 2 94MS36 Rev F2 S W Ver 2 06 ...
Страница 136: ...16 10 94MS36 Rev F2 S W Ver 2 06 ...
Страница 138: ...O Corporation 17112 Armstrong Avenue Irvine Ca U S A 92614 U S A 949 399 6500 Fax 949 399 6501 ...