Page: 106
Service Guide ML380
Chapter 4 Failure & Repair Analysis
Serial Interface Signal Requirements
Pin
Signal
Symbol
Direction
Description
1
Protective Ground
PG
Ground
Connected to the printer frame
2
Transmit Data
TD
From
Printer
Serial data transmitted to the
system
3
Receive Data
RD
To
Printer
Serial data received by the printer
4
Request to Send
RTS
From
Printer
Always set to low (mark)
5
Not Used
6
Data Set Ready
DSR
To
Printer
Indicates that data can be sent
7
Signal Ground
SG
Ground
Ground
8 to
10
Not Used
11
Supervisory Send
Data
SSD
From
Printer
Indicates that the printer is not ready
to receive data
12 to
19
Not Used
20
Data Terminal
Ready
DTR
From
Printer
Indicates that the printer is not ready
to receive data
21 to
25
Not Used
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Содержание ML380
Страница 36: ......
Страница 52: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 56: ......
Страница 87: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 93: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 103: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 132: ...Page 89 Service Guide ML380 Chapter 4 Failure Repair Analysis 4 5 ABNORMAL OUTPUT 4 5 01 Output Samples...
Страница 196: ...Item Okidata P N Oki J P N Description Comments Refer to B 1 02 Disassembly Procedure...