Oki Data CONFIDENTIAL
44158801TH Rev.2
215 /
Table 8-1-1 Operator Alarm (9/9)
Display on Operator Panel
Ready
LED
Attention
LED
Description
Code
nnn
PLEASE POW OFF
SHUTDOWN COMP
Off
Off
It is shown that the printer completed shutdown pro-
cessing. (The backlight of LCD puts out the light)
Printer will be restarted if a SHUTDOWN/RESTART
button is pressed.
Error
POWER OFF AND WAIT FOR A
WHILE
%ERRCODE%:CONDENSING ER-
ROR
Off
Blink
A dew is formed. (Reserved; T.B.D.)
*Fatal Error is not available in national language.
Fatal
126
POWER OFF/ON
%ERRCODE%:FATAL ERROR
Off
Blink
A fatal error occurred.
For more information, see attached 'Fatal Errors
List'.
*Fatal Error is not available in national language.
Fatal
<nnn>
SERVICE CALL
%ERRCODE%:FATAL ERROR
Off
Blink
A fatal error occurred.
For more information, see "Service Calls List."
*Fatal Error is not available in national language.
Fatal
<nnn>
SERVICE CALL
%ERRCODE%:FATAL ERROR *
Off
Blink
A fatal error occurred.
'*' specifies the detailed error cause.
*Fatal Error is not available in national language.
Fatal
096
231
128
168
169
POWER OFF/ON
%ERRCODE%:FATAL_ERROR
nnnnnnnn nnnnnnnn nnnnnnnn
Off
Blink
A fatal error occurred.
For more information, see "Service Calls List."
'nnnnnnnn' specifies the detailed error cause.
*Fatal Error is not available in national language.
Fatal
002
~
011
F0C
F0D
FFE
FFF
POWER OFF/ON
%ERRCODE%:DOWNLOAD ERROR
Off
Blink
Downloading Media Table to PU has failed.
(Related to CustomMediaType.)
*Fatal Error is not available in national language.
Fatal
209