Oki Data CONFIDENTIAL
44158801TH Rev.2
168 /
BELT: Constant speed timer value of belt motor (I/O set value) [Unit: HEX]
FRM : [***] = AD value of frame thermistor reading [Unit: HEX]
(xxx) = Frame temperature [Unit: ˚C]
• Pressing the MENU+ key switches over the indication.
HT: Fuser temperature setup table ID No. [Unit: HEX]
DB: Development voltage setup table ID No. [Unit: HEX]
• Pressing the MENU+ key switches over the indication.
TR1: Transfer voltage parameter VTR1 table ID No. [Unit: HEX]
TR2: Transfer voltage parameter VTR2 table ID No. [Unit: HEX]
• Pressing the MENU+ key switches over the indication.
TROFF: Transfer OFF voltage setup table ID No. [Unit: HEX]
BELT: *** = Belt temperature [Unit: ˚C]
xxx = AD value of belt thermistor reading [Unit: HEX]
5.
Repeat Items 2 to 4, as needed.
6.
Press the CANCEL key to terminate the test. (Status of Item 1 restored)
• Pressing the MENU+ key switches over the indication.
KID, YID, MID and CID denote the constant-speed timer values of the respective ID motors (I/
O set values) [Unit: HEX].
• Pressing the MENU+ key switches over the indication.