background image

 

 

 

24 

 

20.

 

Explanations in other languages - abbreviated version 

 
 

English  

abbreviation 

French  

abbreviation 

Spanish 

 abbreviation 

Full version 

 

 

informaciones sen-
sores 

Span: informaciones de los sensores 

 

valeurs mes. en-
reg.  

valores medición sal-
vado 

Fr : valeurs mesurées enregistrée 
Span : valores de medición salvado 

modif. possible 
by ±%s %s  

change. de ±%s 
%s possible  

 

Eng: modification possible by ±%s 
%s 
Fr:  changement de ±%s %s possi-
ble 

 

plongez capteur 
pH après 

sumerja sensor pH 
después 

Fr: plongez le capteur de pH après 
Span:  sumerja el sensor de pH 
después 

 

nettoyage d. le 
tampon 1  

de la limpieza en 
búfer 1 

Fr: le nettoyage dans le tampon 1 
de la limpieza en búfer 1 

 

nettoyage d. le 
tampon 2 

 

Fr: le nettoyage dans le tampon 2 

measure. process: 
buffer 1 

proces. mesure: 
tampon 1 

proceso medición: 
búfer 1 

Eng: measuring process: buffer 1 
Fr: processure de mesure: tampon 1 
Span : proceso de medición: búfer 1 

measure. process: 
buffer 2 

proces. mesure: 
tampon 2 

proceso medición: 
búfer 2 

Eng: measuring process: buffer 2 
Fr: processure de mesure: tampon 2 
Span : proceso de medición: búfer 2 

 

 

resultado calibración 

Span: resultado de la calibración 

 

enregistrez valeur 
tampon 

 

Fr : enregistrez la valeur de tampon 

 

différ. tampon 
trop faible 

dif. búfer demasiado 
baja 

Fr : différentiel du tampon est trop 
faible 
Span : diferencia entre los búferes 
es demasiado baja 

 

erreur dans la dé-
terminat. 

 

Fr: erreur dans la détermination 

 

 

reemplace el sensor 

Span: reemplace el sensor, por favor 

 

 

dif. búfer demasiado 
baja 

Span: detectada esta demasiado baja 
 

temp. difference 
too high 

différ. temp. trop 
élevée 

dif. temp. demasiado 
alto 

Eng : temperature difference too 
high 
Fr : différentiel de température trop 
élevée 
Span:diferencia de la  temperatura 
esta demasiado alto 

 

 

valor oxígeno 

Span : valor del oxígeno 

 

pression at. 

presión atm. 

Fr: pression atmosphérique 
Span: presión atmosférica  

 

proces. mesure: 
tampon 2 

proceso medición: 
sulfito 

Fr: processure de mesure: sulfite 
Span : proceso de medición: sulfito 

meas. process: 
saturation 

proces. mesure: 
saturation 

proceso medición: 
saturac. 

Eng: measuring process: buffer 2 
Fr: processure de mesure: saturation 

 

confirmez avec 
bouton \"OK 

 

Fr : confirmez avec le bouton \"OK 

Содержание udox

Страница 1: ...dox Operating instructions Version 1 6 8...

Страница 2: ......

Страница 3: ...10 2 Switch on the hand held meter 9 10 3 Switch off the hand held meter 10 10 4 Navigation Program guides 10 11 Calibration 10 11 1 Temperature pH O2 11 11 2 pH value 12 11 3 Oxygen value 13 12 Spec...

Страница 4: ...analytical mechanical or electrical effects of any kind or type 4 Liability The manufacturer accepts no liability for the correctness of measurements This exclusion of liability is based on the fact t...

Страница 5: ...commended storage temperature 15 25 C Intended use of the hand held meter The exclusive intended use of the hand held meter is measuring pH redox dissolved oxygen total hardness and acid capacity in w...

Страница 6: ...ommunications cable for the dox hand held meter 4 Distillate spray bottle for rinsing and cleaning the sensors 5 pH buffer 9 18 6 pH buffer 7 00 7 Sodium sulphite 8 Syringe and tubes 9 Replacement sen...

Страница 7: ...er Socket panel and tightened using the screw connector One or two sensors can be connected whereby the choice of sensors sockets 2 is free Switch the hand held meter on using the key pad ON OFF and c...

Страница 8: ...splay pH lower half O2 sensor 7 8a Unit of oxygen value Transient mode for pH sensor 2 Sensor temperature value 8b Transient mode for O2 sensor 3 4 pH value recorded Redox potential recorded 9 Current...

Страница 9: ...values on the display should be noted Calibrate the sensor Reminder 3 x flashes after switching on the device remind you that the last calibration took place over 30 days ago This display only acts as...

Страница 10: ...rted at any time 11 Calibration Why is calibration necessary Because sensors age and change their behaviour This leads to imprecise measurements Cali bration continuously updates the internal behaviou...

Страница 11: ...e exposed to a very constant temperature for 10 minutes To avoid extreme changes the temperature range can only be changed by 1 C 11 1 Temperature pH O2 The calibration can be aborted at any time usin...

Страница 12: ...o change to pH value or pH redox value of the selected sensor and confirm with OK 4 After cleaning with distilled water dip the pH sensor in buffer 1 Note 20 ml in sensor vial Confirm with OK Calibrat...

Страница 13: ...lly Go back to menu selection with OK 11 3 Oxygen value The calibration can be aborted at any time using the key 1 Open the menu selection using MENU 2 Confirm calibration with OK 3 Use or to change t...

Страница 14: ...ious samples We recommend cleaning the sensors and sensor vials with dis tilled water after contact with a liquid The volumes and mixing ratios must be followed precisely Reagent solutions must always...

Страница 15: ...several times Start the measure ment process with OK 8 Measurement process The sample is measured duration 60 seconds 9 Confirm measurement with OK 10 Display of oxygen capacity Confirm measurement w...

Страница 16: ...onds 6 Confirm measurement with OK 7 Add 0 4 ml RM B Insert the sensor in the sensor vial shake slowly several times Start the measure ment process with OK 8 Measurement process The sample is measured...

Страница 17: ...day month year DD MM YY The order of the time units is fixed Calibration interval The manufacturer recommends calibrating the sensor every 30 days This time interval is fixed You will find more inform...

Страница 18: ...shown by time in ascending order The current measurement site and total measurement sites are shown in the uppermost line In the example 1 17 i e measurement point 1 of 17 Explanation of further valu...

Страница 19: ...nsors Delete measurement data Open the menu selection with MENU and use or to go to the sub menu measure ment sites measurement data Confirm with OK Navigate using or to the function delete data and c...

Страница 20: ...e is highlighted in black again Unit of measure options for temperature Temperature can be shown either in degrees Celsius C Kelvin K or Fahrenheit F Degrees Celsius Kelvin Fahrenheit 1 C 274 15 K 33...

Страница 21: ...he simplest case it is shown as a mass share in g kg grammes of salt per kilogram of saline water or solution or in percent 1 corresponds to 10g kg To determine the exact salt content the liquid must...

Страница 22: ...the battery and the operating time of the dox hand held meter is reduced Time Time is shown in the following order hours minutes seconds HH MM SS and the time can be amended The order of the time unit...

Страница 23: ...s no exchange of the solutions to avoid faulty measurements Therefore the sensors should always be cleaned with distilled water as part of measurements and calibrations in accordance with the instruct...

Страница 24: ...suring process buffer 2 Fr processure de mesure tampon 2 Span proceso de medici n b fer 2 resultado calibraci n Span resultado de la calibraci n enregistrez valeur tampon Fr enregistrez la valeur de t...

Страница 25: ...measuring proce dure Fr apr s d marrez le processus de mesure Span d spues empiece el proceso de medici n determin acidity capacity determin capacit l acide determin capacidad cido Eng determination...

Страница 26: ...ssolution 1 8 ppm Accuracy 5 Measurement single point process with reagent Acid capacity Measuring range ANC 8 2 p value 0 10 mval l ANC 4 3 m value 0 10 mval l Dissolution 0 01 mval l Accuracy 5 Meas...

Страница 27: ...1 2010 For verification in accordance with EMC Directive 2014 30 EU the following standards were applied For verification in accordance with EMC Directive 2014 30 EU the following standards were appl...

Страница 28: ...OFS Online Fluid Sensoric GmbH Heidelbergweg 9 07580 Ronneburg Germany Operating instructions dox Version 1 6 8 Issue 06 2020 Subject to technical change without notice...

Отзывы: