9.7.2
Fibre check
If the deviation is higher than expected, check power directly at the laser module:
STEP 1:
1.
2.
3.
4.
5.
6.
7.
Disconnect fibre cable from laser
module.
Protect end of fibre cable with the
cap attached to the fibre itself.
Connect test fibre of measuring sen-
sor head to laser module.
Set external fibre detection to
“NO”
(see
Measure power and compare it with
the intended value.
If the value is within the tolerance,
exchange the fibre (see
Calibrate as described in
If the power at the module itself matches the values submitted at the software, then the power loss is caused by the fibre