Basics
7
www.ocularrobotics.com
Ocular Robotics Ltd
a)
The camera lens should be rotated on the filter thread where it attaches to the
REV25-ST by the minimum amount required to align the body of the camera to
one of the two possible camera mount positions shown in Figure 3.11.
b)
Remove two socket head screws in the base of the REV25-ST body in the chosen
position for the attachment of the camera mount (
DO NOT
have any more than
two screws removed from the base of the REV25-ST at any time). Place the
camera mount in position and replace the socket screws but do not tighten until
the mount is attached to the camera.
c)
Use fasteners appropriate for your camera to fasten the camera to the mount and
then tighten the socket screws attaching the mount to the base of the REV25-ST
(Note – The screws used to attach the camera to the mount will need to be
loosened to focus the camera).
9.
Attach power and communications cables as appropriate for your camera.
2.4.2
REV25-ST VISION - STABILIZED System
Follow the steps below to set the REV25-ST system up for use on a computer with a
Windows or Linux operating system. The library version number and system IP address
shipped with your system should be noted on the supplied
Certificate
.
1.
Connect one end of the Ethernet cable to the network port on the PC or Switch.
Connect the other end to the REV25-ST Control Ethernet port (right-side Ethernet
connector). Refer to Figure 2.5.
2.
Connect another Ethernet cable to the REV25-ST Camera Ethernet port (left-side
Ethernet connector) and a PC or Switch.