General Description
14
www.ocularrobotics.com
Ocular Robotics Ltd
supply. The cable with the red sheath should be connected to the positive terminal on
the power supply.
During connection of the power supply cable to the corresponding plug on the REV25-
ST system, ensure the correct orientation by aligning the polarisation keys on the panel
connector and the plug. If forced in the incorrect orientation, damage to the system is
likely to result.
A 16A rated slow blow fuse is housed in the fuseholder to prevent potential damage to
internal electrical components from power surges.
Figure 3.2 – Fuseholder on the REV25-ST Enclosure
Power to the camera inside the enclosure is provided via a two-way connector. The red
wire provides 24 VDC with respect to the black wire at 0 V. A suitable voltage converter
is required if the camera operates at a different voltage.
Figure 3.3 – Power connector for the camera