Chapter 3 : Setting up the unit
37
AP-75037, Rev. 1.1, 24/04/2006
3.4 INSTALLATION
Product installation is explained below.
3.4.1 Choosing a place for the printer
Install the unit on a proper location referring to the following :
Warning :
•
Do not place the printer on a location under the following conditions. Doing so
may cause the product to fall, become damaged, or cause injury.
o
Unstable surfaces
o
Sloping surfaces
o
Locations that are subject to vibration from other products.
•
Do not stand on the printer or place heavy objects on it. Doing so may cause it
to fall over, become damaged, or cause injury.
•
Do not cover the ventilation hole of the printer with cloth, such as a blanket or
table cloth. Doing so could prevent the printer from ventilating and cause fire.
•
Keep the printer away from humid and dusty areas. Humidity may result in
electrical shock or fire.
3.4.1.1 Installation environment requirements
Choose a place for printer installation following the requirements in the table below.
65” model
12.7m² (144ft²) or larger. Frontage of 4.7m (15.7ft) or more.
Area
90” model
14.3m² (162ft²) or larger. Frontage of 5.3m (17.7ft) or more.
Floor loading capability
2940Pa (300kg/m²) or more
65”
90”
Voltage AC
100-120V
AC 220-240V
AC 100-120V
AC 220-240V
Frequency 60/50Hz±1Hz 60/50Hz±1Hz
Electrical
Capacity
AC100V-120V : 12A
AC220V-240V : 6A
AC100V-120V : 13A
AC220V-240V : 7A
In order to protect the printer for over currents, short circuits and earth faults, the building
installation should be equipped with an automatic breaker double pole of 20 A and an earth leakage
switch of 300 mA.
Recommended
working
environment
Temperature: 23°C
Humidity: 55%, without condensation
Operational
conditions
Temperature: 18°C-28°C
Humidity: 40% to 80%, without condensation
Rate of change
Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Ambient
conditions
Storage and
transport
conditions
Temperature: 4°C to 50°C
Humidity: 40 to 80%, without condensation (When ink has been
discharged.)
Содержание CS9065
Страница 1: ...Océ CS9065 Océ CS9090 User Guide Eco Solvent ...
Страница 12: ...Chapter 1 Safety Instructions 12 AP 75037 Rev 1 1 24 04 2006 No Type 1 2 3 4 5 ...
Страница 24: ...Chapter 2 Product Overview 24 AP 75037 Rev 1 1 24 04 2006 This page is intentionally left blank ...
Страница 78: ...Chapter 4 Preparing for a job 78 AP 75037 Rev 1 1 24 04 2006 This page is intentionally left blank ...