5.5.1.4 Change the dryer temperature
To change the temperature of the dryers, press the [F4] key on the operation panel. The display will mention
the following:
Press the [F2] key to decrease the temperature.
Press the [F4] key to increase the temperature.
Press the [ENTER] key to confirm the requested temperature change.
Press the [CANCEL] key to leave the menu without changing the rear heater settings.
* Drier (D) *
OFF – 50°C
+
←
F2
50°C -
←
F4
F2, F4
→
ENTER
5.5.1.5 Activate/ deactivate heaters.
In the second menu, press the [F1] key to activate or deactivate all heating elements.
In case the heating elements are activated, the display will mention “SET OFF”. By pressing the [F4] key
you can deactivate the heating elements. The display will mention “SET ON”.
In case the heating elements are deactivated, the display will mention “SET ON”. By pressing the [F4] key
you can activate the heating elements. The display will mention “SET OFF”.
Please note that after finishing a printing job (and no other print job is sent to the printer the heating elements
will keep their temperature for approximately 6 minutes. After 6 minutes the heating elements are powered
OFF.
Содержание CS9065
Страница 1: ...Océ CS9065 Océ CS9090 User Guide Eco Solvent ...
Страница 12: ...Chapter 1 Safety Instructions 12 AP 75037 Rev 1 1 24 04 2006 No Type 1 2 3 4 5 ...
Страница 24: ...Chapter 2 Product Overview 24 AP 75037 Rev 1 1 24 04 2006 This page is intentionally left blank ...
Страница 78: ...Chapter 4 Preparing for a job 78 AP 75037 Rev 1 1 24 04 2006 This page is intentionally left blank ...