9.8 Sensor Supplies
PCM2 has 3 stabilised 5.0 Volts sensor supplies (VREF) for use with the analogue sensor inputs.
Maximum current draw from each output is 1.0 A.
9.8.1 Pin Configuration 5 Volt VREF Outputs
Channel
Max continuous
current, A
Max recommended
current, A
Connector 4
Pin
VREF1
1.0
1.0
AS2 16-35 SN
32
VREF2
1.0
1.0
AS2 16-35 SN
40
VREF3
1.0
1.0
AS2 16-35 SN
47
9.9 Warning Light
PCM2 is equipped with a warning light for error detection. The driver output is found in connector
4, pin 42. If a fault is detected, the channel switches 5.0 volts ON, maximum current draw is 1.0 A.
9.10
Fault Reset
You can reset all output channels in error status by briefly connecting the selected reset channel to
ground.
A reset channel can be assigned as an event. In this case any input - analogue, digital or CAN –
and the dedicated warning light output can be assigned.
Use the event settings to define the switching conditions.
Resetting PCM2 only affects channels in error state. The reset function will not reboot the PCM in
general and has no influence on outputs in normal operation state. It will only reboot channels
which have switched off after their pre-defined automatic resetting conditions.
Please see section 5.3.1.13 for setting up a reset event.
The reset will reboot channels which were shut down due to overload of OCH, OCL and OCS.
9.10.1
Pin Configuration Warning Light Output
Channel
Max current, A
Connector 4
Pin
WL1
5.0 Volts @ 1.0 A
AS2 16-35 SN
42