The map can be imported and exported to Excel.
An easy way to create a frequency map is to follow this procedure:
Open the frequency map
Click “Copy”
Paste into Excel
Modify table
Mark the table and copy
Return to the tool and click past
Set the applied duty cycle percentage; values can be between 5 and 99%
The
Status
window shows the real time current draw of the output in mA.
Use the
Manual
option to test the output connection. When
Manual
is active (see section
4.3
),
PCM2’s event handling has been deactivated and all channels are OFF by default.
Click the ON button for each individual channel to switch the output ON.
Click the ON button again to switch the output OFF.
Clicking on
Trigger
will open the main event controlling this output. A warning may appear if
several events are used to control it.
The status window will show the real time current draw of the output in mA.
Use the
Manual
option to test the output connection. When
Manual
is active (see section
4.3
),
PCM2’s event handling has been deactivated and all channels are OFF by default.
Click the ON button for each individual channel to switch the output ON.
Click the ON button again to switch the output OFF.
Clicking on
Trigger
will open the main event controlling this output. A warning may appear if
several events are used to control it.
9.3.3 Pin Configuration Low Power PWM Outputs
LP PWM OUT
Max continuous
current, A
Max recommended
current, A
Connector 3
Pin
1
25
13
AS2 20-39 SA
k
2
25
13
AS2 20-39 SA
V
3
25
13
AS2 20-39 SA
j
4
25
13
AS2 20-39 SA
W