Control Systems
OBR Control Systems Inc
OBR Control Systems Inc
Telephone : +1 (248) 672-3339
32233 West 8 Mile Road
www.obrcontrolsystems.com
Livonia, Michigan 48152
USA
88 / 92
16.4
Connector 4 – Signal and Inputs
Mating connector: Deutsch AS6 16-35 PN or Souriau 8STA61635PN
Pin
Used for
Comments
1
Digital Input 7
Trig High / Low / Open
2
Digital Input 5
Trig High / Low / Open
3
Digital Input 3
Trig High / Low / Open
4
Digital Input 11
Trig High / Low / Open
5
Digital Input 9
Trig High / Low / Open
6
Digital Input 6
Trig High / Low / Open
7
Digital Input 2
Trig High / Low / Open
8
Digital Input 1
Trig High / Low / Open
9
CAN 3H
10
Digital Input 13
Trig High / Low / Open
11
Digital Input 12
Trig High / Low / Open
12
Digital Input 8
Trig High / Low / Open
13
Digital Input 4
Trig High / Low / Open
14
CAN 4H
15
CAN 2L
16
CAN 2H
17
RS232 TX
18
RS232 RX
19
Digital Input 14
Trig High / Low / Open
20
Digital Input 10
Trig High / Low / Open
21
CAN 4L
22
CAN 3L
23
CAN 1L
24
CAN 1H
25
LIN bus LIN_MST
Connect to 26 to set as MASTER
26
LIN bus LIN_BUS
27
Ethernet TX-
Reserved for future use
28
Ethernet TX+
Reserved for future use
29
Ethernet RX+
Reserved for future use
30
Ethernet RX-
Reserved for future use
31
Analogue Input 16; 12 bit
Pull-up 0 / 3.16k / 47k
32
Sensor supply VREF1
5.0 volt @ 1.0 A
33
Analogue ground
34
Analogue ground
35
Analogue ground
36
Analogue ground
37
Analogue Input 12; 12 bit
Pull-up 0 / 3.16k / 47k
38
Analogue Input 14; 12 bit
Pull-up 0 / 3.16k / 47k
39
Analogue Input 15; 12 bit
Pull-up 0 / 3.16k / 47k
40
Sensor Supply VREF2
5.0 volt @ 1.0 A
41
Analogue ground
42
Warning Light + Reset
5.0 volt @ 1.0 A
43
Analogue Input 4; 12 bit
Pull-up 0 / 3.16k / 47k
44
Analogue Input 8; 12 bit
Pull-up 0 / 3.16k / 47k
45
Analogue Input 10; 12 bit
Pull-up 0 / 3.16k / 47k
46
Analogue Input 13; 12 bit
Pull-up 0 / 3.16k / 47k
47
Sensor Supply VREF 3
5.0 volt @ 500 mA
48
Analogue Input 1; 12 bit
Pull-up 0 / 3.16k / 47k