Maintenance and cleaning
Switch the unit off with the main switch and pull the power plug. Remove all hoses and the motor housing (C). Turn the
inlet distributor (D1) out of the bajonet closure and, if required, remove the inner tank (D2) from the holder. Thoroughly
rinse the collection container to remove all dirt particles. This also applies to the inlet distributor (D1) and the outlet valve
(F1). Remove the foam filter (E1) by unbolting the engagement plates (E2) and wash out with clean water. Check the
foam filter (E1) and, if damaged, replace this wearing part by an original OASE foam filter.
Check sealing rings for damage and completeness. If necessary, change the rubber seals in the inlet distributor (D3) and
in the drain valve (F2). Inlet distributor: to be turned out. Drain valve: Remove screw from inside the tank.
Please contact your specialist dealer when the distributor unit (E3) requires maintenance!
Wearing parts
Foam filter, sealing rings and valve rubber parts are wearing parts and are, therefore, not covered by our warranty.
Storage
Empty out the collection container and clean the unit. Store in a dry, frost protected room, inaccessible to children.
Disposal
Dispose of the unit in accordance with the national legal regulations.
Malfunctions
The unit does not perform its suction function, generates unusual noise or heavily vibrates (G1). Turn the unit off at the
main switch (G2) and on again after 20 seconds. If the fault reoccurs, either the tank is full (with the closing plug inserted)
or the inlet distributor, the return or the foam filters are soiled (G3). See maintenance and cleaning!
Remarques relatives à cette notice d'emploi
Avant la première utilisation, lire attentivement cette notice d'emploi et se familiariser avec l'appareil. Respecter
impérativement les indications de sécurité relatives à une utilisation correcte et en toute sécurité.
Utilisation conforme à la finalité
Le Pondovac 3, nommé par la suite appareil, est un aspirateur uniquement réservé pour aspirer la vase ou comme
aspirateur pour eau. Une aspiration continue avec vidange automatique est possible en mode automatique.
Utilisation non conforme à la finalité
En cas d'utilisation non conforme à la finalité et de manipulation non appropriée de cet appareil, des risques pour les
personnes peuvent en résulter. Toute utilisation non conforme à la finalité entraîne l'annulation de notre responsabilité
ainsi que de l'autorisation d'exploitation générale.
Trouble shooting
Cause
Remedy
The unit does not perform its
suction function, generates
unusual noise or heavily
vibrates (G1).
- Either the tank is full (with the closing plug inserted) or
the inlet distributor, the return or the foam filters are
soiled (G3).
- Turn the unit off at the main switch (G2) and on again after 20
seconds
- See maintenance and cleaning!
The unit does not suck/its
performance reduces
- Excessive height difference between water level and
unit
- Flaps at the inlet distributor (D1) are jammed / soiled
- The outlet flap is jammed / soiled
- O ring at the inner tank (D2) not properly seated
- O ring at the inlet distributor (D2) not properly seated
- O ring at the valve unit (E3) not properly seated
- Both containers are full of water and completely sealed
by the floats
- Dirt has accumulated in the foam filter, in the suction
tube or in the suction hose
- We recommend to place the unit at a height identical to the
water level
- Remove the inlet distributor (D1) and check the flap seating
- Remove the drain hose and check the flap seating
- Check the O ring seating
- Check the O ring seating
- Check the O ring seating
- Switch off and drain the unit
- Remove dirt
The container does not
empty
- Drain openings (C3) or the drain hose are plugged
- The drain hose is kinked or was not laid with a gravity
drainage
- Remove dirt from the drain openings (C3) and the drain hose
- Lay the hose without kinks and, if possible, with a slight grav-
ity drainage
Low suction capacity
- The larger the number of tubes used, the higher the tube
frictional resistance. The suction capacity reduces.
- The larger the height difference between water level and
unit, the lower the effective suction capacity
- Keep the suction hose as short and flat as possible
- Remove the non-return valve at the nozzle
Formation of vapour during
operation
- Water drops sucked through the turbine. Heated, humid
air condenses when leaving the turbine housing
- This is normal, especially at low temperatures
The unit operates erratically
- Soiling in the drain (C3)
- Switch the unit off and check for soiling
Switch-over problems of the
unit between the containers
are encountered
- The valve unit does not function correctly
- Leaks at the O ring sealed points
- Check the smooth movement of the valve plates
- Check O rings
F
GB
Содержание PondoVac 3
Страница 4: ...4 B A D 2 1 2 1 C 2 1 1 2 1 4 E 2 1 3 2 1 2 3 F G 1 2 3 3 3 3...
Страница 41: ...41 30 mA A2 1 2 D2 3 1 2 2 2 0 3 180 D4 10 C D1 D2 D1 F1 1 2 1 OASE D3 F2 3 BG...
Страница 42: ...42 G1 G2 20 G3 Pondovac 3 G1 G3 G2 20 D1 O D2 O D1 O 3 D1 C3 C3 C3 UA BG...
Страница 44: ...44 D1 F1 E1 E2 E1 OASE D3 F2 E3 G1 G2 20 G3 Pondovac 3 G1 G3 G2 20 D1 D2 D2 D2 D1 D1 C3 C3 C3 RUS UA...
Страница 46: ...46 C D1 D2 D1 F1 E1 E2 E1 OASE D3 F2 E3 G1 G2 20 o G3 G1 o G3 G2 20 D1 D2 D1 E3 D1 C3 C3 C3 RUS...
Страница 48: ...48 G1 G2 20 G3 G1 G3 G2 20 D1 D2 O D1 O E3 O D1 O O O C3 C3 C3 O O RC...