28
ENGLISH • Instructions manual
TC 110 - Liga C 200
TC 110 - Liga C 200
WARNING!
Before making any inspection, adjustment or repair be certain power source is disconnected:
1) disconnect the machine from the mains electric supply.
2) disconnect the machine from the compressed air circuit by detaching the compressed air line from the quick couple.
Perform the following routine maintenance operations:
1)
From time to time (about every 15 days) check the oil level in the lubricator, which should be between the “MIN” and “MAX” indicators on the
jar (
1, Fig. P
).
Top up as needed as follows:
- Unscrew the jar (
1, fig. P
)
- Top up with
ISO VG 32
viscosity
ISO HG
class oil for compressed air circuit (such as
ESSO Febis K32; Mobil Vacouline Oil 1405; KLUBER Airpress
32
).
2)
Every 2 or 3 days check if after every 2 or 3 pedal movements (
3 or 5, Fig. H
) a drop of oil falls
into the lubricator glass cup.
If it does not, adjust the lubricator regulating screw using a screwdriver (
see Fig. P
).
3)
Clean the machine daily to remove any dirt or tyre debris from the wheel clamp jaw slides.
Lubricate these slides using
ISO VG 68
viscosity
ISO HG
class grease (such as, for example
ESSO
Febis K68; Mobil Vactra 2; Shell Tonna Oil 68
).
4)
To ensure correct operation of the inflation device pressure limiter (Refer to the section on
“SAFETY DEVICES”, p. 19 of this manual, it is
essential
to carry out the following routine checks:
- Check the water level in the water trap to the air supply (
2, Fig. P
), which must NEVER exceed
the “MAX DRAIN” level indicator on the water trap itself.
When necessary, drain the water by turning the locking ring (
3, Fig. P
) clockwise.
- Every 30-40 days disconnect the machine from the compressed air circuit and dismantle the glass
(
2, Fig. P
) to remove any solids collected inside it.
11. ROUTINE MAINTENANCE
P
1
2
3
12. FIRE-FIGHTING
13. MOVING THE MACHINE
Follow the procedures outlined below when moving the machine:
1)
Close the turntable grippers all the way towards the centre.
2)
Turn the table so to position the slots on the turntable plate as shown in
Fig. Q/1
.
3)
Disconnect all power sources.
WARNING!
If this machine catches fire, only use powder extinguishers or, alternatively, CO
2
extinguishers to put out the
flames.
Q/1