Output Short Circuit Protection
G3 Output modules incorporate short circuit protection and diagnostics to identify short circuit, open coils and
over temperature conditions. The diagnostics can be accessed within the user PLC program or the G3
EtherNet/IP
TM
node’s integrated web page. Detailed information regarding these features can be found on page
147.
Output Type
Output
State
Fault Condition
Status
Bit
Valve Solenoid Coil Driver
ON
No Fault
0
Fault - Short Circuit, Over Temp/Over Current
1
Valve Solenoid Coil Driver
OFF
No Fault
0
Fault - Open Load
1
Discrete Outputs
ON
No Fault
0
Fault - Short Circuit, Over Temp/Over Current
1