Section 8
Troubleshooting
Alpha Fuzion Sauna Body Pod
86
VII. Aroma Oil not being Dispersed
A.
Check LCD indicator on display screen CONTROL PANEL to verify if aroma is ON.
B.
Check corresponding aroma nebulizer for actual amount of oils. Please keep aroma
oil bottles completely full with
Pure Essential Oils and Blends
for optimal
performance.
C.
Properly functioning nebulizer assembly should evidence mist of oil spraying from
small orifice in top of brass nebulizer into glass chamber. If this is not present, got to
next step.
D.
Check small plastic capillary tube connected to under-side of brass nebulizer. If
loose, clogged or collapsed, replace.
E.
Verify appropriate connection of air hose to nebulizer and aroma pump.
F.
Verify air flow through hose to brass nebulizer.
G.
Verify O-ring present between oil bottle and brass nebulizer.
H.
Nebulizer orifice may be clogged. Clean as follows:
1. Remove nebulizer from system.
2. Rinse/soak in alcohol or hot soapy water to loosen clog.
3. Re-install nebulizer in system.
4. Activate pump, blocking small orifice on top with finger, using air to ‘back-
flush’ the nebulizer.
5. If air or oil still do not flow through orifice of nebulizer, insert a very, very fine
wire into the orifice to penetrate the clog and clear a pathway.
6. If air and oil still do not flow through orifice into glass chamber when system
is activated, replace brass nebulizer.
VIII. Ultraviolet Sanitary Lamp Inoperative
A.
Select a program from display screen CONTROL PANEL. Set ultraviolet lamp to ON
position.
B.
Check lamp under the contour bed for operation. If bulb is not operating, then check
the following:
1. Signs of burnout, such as filament inside lamp and discoloration of bulb
glass. If lamp appears to be burned out, replace. If lamp appears
undamaged or replacement does not resolve the problem, go to next step.
2.
Disconnect Alpha Fuzion Sauna Body Pod from power source.
Remove main power box (See Section 7.10) and check for firm plug
connection of lamp assembly cord into outlet on side of power box and firm
terminal connection to ballast attached to side of power box. If connections
are firm, go to next step.
3. Re-power Alpha Fuzion Sauna Body Pod. Select and start a program.
Manually check display panel LCD to ensure the UV lamp is in the ON
position.
CAUTION: High Voltage in this area.
Use a voltmeter to check the receptacle of lamp plug for 110-120 Volts. If
correct voltage is present, move to next step.
NOTE: If no voltage is
present, verify that the display board indicates this apparatus is ON.
Then consult your supplier for additional troubleshooting assistance
or replacement parts, or go to next step.