Section 8
Troubleshooting
Alpha Fuzion Sauna Body Pod
83
C.
If connection is correct, turn power ON, select and start program. If heat does not
come on in 1-2 minutes, go to next step.
D.
Verify power and viability of heater and circuit using volt/ohm meter.
1. Disconnect heater harness from base.
CAUTION: High Voltage in this area.
2. Check across male pins number 9 & 14 of connector for reading of 26-27
Ohms to validate circuitry of heater core. If no Ohms reading, heater core
may be bad. Replace main heater assembly. If Ohms OK, go to next step.
3. With heater still disconnected, select and start a program.
CAUTION: High Voltage in this area
.
Carefully check for voltage across female pins of heater connector as
follows:
a. Pins 1 & 2
110/120 Volts
b. Pins 9 & 14
220/240 Volts
If either of these voltages is not present, go to next step.
E.
Disconnect unit from power and carefully remove main power box (See Section
7.10).
1. Check connector lugs (5) from main box to extension harness from main
heater for good connection.
NOTE: Verify good connection of all other
connectors into main box, as well.
Re-install main power box, being
careful not pinch any wires. Re-power unit.
2. Select program and start, waiting 1-2 minutes for heater to initiate, or repeat
voltage check (Step D-3 above). If heat or voltage still not present, consult
supplier for additional technical assistance.
III. No Power to Display Screen / Control Panel.
A.
Check plug connection into wall receptacle
B.
Check plug connection into receptacle in base of Alpha Fuzion Sauna Body Pod.
C.
Verify proper incoming power (220-240 Volts) from wall.
D.
Check breaker switch on main power box on deck of base, under the contour bed.
Switch should be in ON position.
E.
Display panel out, but stereo still has power. Possible blown fuse in F1 position of
Main Power Box:
•
WITH POWER DISCONNECTED, unplug and remove bed assembly from
the unit.
•
Remove the four screws holding down the Main Power Box and cover plate
(see service Chapter 7.10).
•
In the fuse block on the bottom of the power box, observe the fuse in the F1
position, which is on the end nearest the terminal block, next to the empty
fuse space. (See diagram A-1 in this manual). If this fuse is blown, replace
with a
4 Amp 250v Slow-blow type fuse
.
•
If this does not resolve the problem, check additional items below.
Содержание Alpha Fuzion
Страница 1: ...206507 NA AF 10 0813 2 U...