Section 8
Troubleshooting
Alpha Fuzion Sauna Body Pod
84
F.
Check for low voltage power loss as follows:
1.
Check data harness connection between hood and base to
right
of
Main Hinge/Strut Assembly as shown in Figure 7.10.5
Connector
Diagram
.
Must be aligned correctly and twist-locked in place.
2.
Check the low voltage regulator screw. This screw is near the main
breaker switch on top of the main power box as shown in Appendix A
Figure A–1
Power Supply Box
, and is accessible by unplugging and
removing the contour bed and the four screws holding the main box
protective cover in place. When exposed, tighten screw firmly using
small Phillips screwdriver.
Do not over-tighten.
3.
Low voltage power connector inside Main Box as shown in Appendix A
Figure A–2
Power Supply Box PCB Layout
.
DANGER-High Voltage in
this area
.
a. WITH POWER DISCONNECTED, check for firm contact of 3-pin
connector to printed circuit board of main box. (This connection
supplies all low voltage to the unit. Only two wires are in this
connector.) Re-install main power box and re-assemble. Turn
power ON. If display panel still will not light, re-check DATA
HARNESS connection to right of main hinge. This connection is a
common problem area, especially re-assembly following
installation.
G. If display is still inoperative:
1. Carefully remove three screws, holding display panel in place.
2. Carefully remove display assembly from hood.
3. Verify firm connection of five-pin power connector to PC board from upper
harness.
4. Re-install display panel assembly.
Take care to tighten screws partially
,
in a
rotational pattern
, until all are snug.
Do not over-tighten
.
H. If display is still inoperative, consult supplier for additional technical assistance.
IV. Intermittent Operation (runs a few minutes and quits, then resets)
A. Check and tighten the small screw next to the main switch on top of the main power
box.
1. Remove the 4 screws from the power box cover and use a small Phillips
Head screwdriver to check this screw, which attaches to the 12V regulator
underneath.
2. Tighten as needed, but DO NOT OVERTIGHTEN.
V. Face Fan Inoperative
A. Select and start a program and adjust face fan setting to level five. If no response,
then refer to the following:
1. If fan frame is binding,
slightly
loosen screws in mounting of face fan. If no
improvement, go to next step.
2. Disconnect Alpha Fuzion Sauna Body Pod
from power source.
3. Remove main power box (See Section 7.10).
4. Check for appropriate contact of two-pin connector from face fan harness to
rear side of power box, as shown in Figure 7.10.5
Connector Diagram
. At