Section 7
Service
Alpha Fuzion Sauna Body Pod
77
•
Upper Chassis Data Harness Removal:
1. Remove display/control panel (See Session.7.19), carefully disengage cables from
PC board and radio, and carefully set aside.
2. Remove Alpha Fuzion Sauna Body Pod hood section (See Session 7.1) and place
upside-down on padded work surface (floor, cart, etc.).
3. Disengage main heater assembly from hinge plate (See Session 7.3, Step 1) and
let it rest within the heat channel, giving access to the upper data harness.
4. Release black screen on data harness side by straightening tabs within heat
chamber and remove.
5. Using wrench, release cable as shown in Figure 7.23.11
Removing/Installing
Upper Harness Cable
from heat chamber area by loosening plastic nut of strain
relief and sliding out of slot. Push harness and connector through heater vent
opening and pull through opening in hinge plate.
6. Remove upper chassis harness by grasping the black connector and
CAREFULLY
pulling entire assembly from its channel in the hood. Pull it through
the opening vacated by the heater assembly (in the foot end of the hood) and out
through the hinge plate. If cable is to be discarded, it can be cut and resulting
segments can be pulled through each end of hood.
Figure 7.23.11 Removing/Installing Upper Harness Cable.
Содержание Alpha Fuzion
Страница 1: ...206507 NA AF 10 0813 2 U...