Section 7
Service
Alpha Fuzion Sauna Body Pod
51
Figure 7.10.3 Disconnecting Transformer from Power Box.
•
Main Power Supply Box Replacement Steps:
1. Set replacement power supply box on foam pad (or heavy cloth) on base chassis.
2. Connect aroma pumps as follows:
•
Pump one: upper left outlet.
•
Pump two: lower left outlet.
•
Pump three: upper right outlet.
•
Pump four: lower right outlet.
3. Connect sanitary lamp to single receptacle on box as shown in Figure 7.10.4
Aroma Pump Wiring Connection
.
4. Connect ballast transformer (still connected to wiring harness) to side of box.
5. Connect two-pin and six-pin connectors to power supply box as shown in Figure
7.10.5
Connector Diagram
.
6. Connect black/red connector to transformer in cavity of base.
7. Connect heater output wires (5) to heater harness (blue to blue, brown to brown,
ground to ground).
8. Connect input power connection:
•
Green wire attaches to ground terminal.
•
Blue wire attaches to top right terminal.
•
Brown wire attaches to top left terminal.
9. Carefully place power box in base chassis.
(Be careful not to pinch or chafe
wires.)
10. Replace cover and install screws.
CAUTION: Overtightening may cause cracking in chassis.
Содержание Alpha Fuzion
Страница 1: ...206507 NA AF 10 0813 2 U...