5.Operation
Group A General output terminal output condition
/ Monitor output selection/ Serial communication settings
5-70
ID
Contents
Setting range
Unit
Standard value
11 Analog Monitor Select Output 1 [MON1]
00 to 1C
-
05:VMON_2mV/min
-1
12 Analog Monitor Select Output 2 [MON2]
00 to 1C
-
02:TCMON_2V/TR
■
Select output signals to output to Analog monitor 1 and 2 from the list below:
01:TMON_2V/TR
Torque Monitor
2V/Rated torque
02:TCMON_2V/TR
Torque Command Monitor
2V/Rated torque
03:VMON_0.2mV/ min
-1
Velocity Monitor
0.2mV/min
-1
04:VMON_1mV/ min
-1
Velocity Monitor
1mV/min
-1
05:VMON_2mV/ min
-1
Velocity Monitor
2mV/min
-1
06:VMON_3mV/ min
-1
Velocity Monitor
3mV/min
-1
07:VCMON_0.2mV/ min
-1
Velocity Command Monitor
0.2mV/min
-1
08:VCMON_1mV/ min
-1
Velocity Command Monitor
1mV/min
-1
09:VCMON_2mV/ min
-1
Velocity Command Monitor
2mV/min
-1
0A:VCMON_3mV/ min
-1
Velocity Command Monitor
3mV/min
-1
0B:PMON_0.01mV/P
Position Deviation Counter Monitor
0.01mV/Pulse
0C:PMON_0.1mV/P
Position Deviation Counter Monitor
0.1mV/Pulse
0D:PMON_1mV/P
Position Deviation Counter Monitor
1mV/Pulse
0E:PMON_10mV/P
Position Deviation Counter Monitor
10mV/Pulse
0F:PMON_20mV/P
Position Deviation Counter Monitor
20mV/Pulse
10:PMON_50mV/P
Position Deviation Counter Monitor
50mV/Pulse
11:FMON1_2mV/kP/s
Position Command Pulse Frequency
Monitor 1 (Position Command Pulse
Input Frequency
2mV/kPulse/s
12:FMON1_10mV/kP/s
Position Command Pulse Frequency
Monitor 1 (Position Command Pulse
Input Frequency)
10mV/kPulse/s
13:FMON2_0.05mV/kP/s
Position Command Pulse Frequency
Monitor 2 (Position Command Pulse
Frequency for Position Control)
0.05mV/kPulse/s
14:FMON2_0.5mV/kP/s
Position Command Pulse Frequency
Monitor 2 (Position Command Pulse
Frequency for Position Control)
0.5mV/kPulse/s
15:FMON2_2mV/kP/s
Position Command Pulse Frequency
Monitor 2 (Position Command Pulse
Frequency for Position Control)
2mV/kPulse/s
16:FMON2_10mV/kP/s
Position Command Pulse Frequency
Monitor 2 (Position Command Pulse
Frequency for Position Control)
10mV/kPulse/s
17:TLMON_EST_2V/TR
Load Torque Monitor
(Estimated Value)
2V/Rated torque
18:Sine-U
U Phase Electronic Angle Sin
8Vpeak
19:ACMON_0.01mV/rad/s
2
Acceleration monitor
0.01mV/rad/s
2
1A:ACMON_0.1mV/rad/s
2
Acceleration monitor
0.1mV/rad/s
2
1B:ACMON_1mV/rad/s
2
Acceleration monitor
1mV/rad/s
2
1C:ACMON_10mV/rad/s
2
Acceleration monitor
10mV/rad/s
2
◆
Position command pulse frequency monitor 1 monitors Position command pulse before
the Electronic gear.
◆
Position command pulse frequency monitor 2 monitors Position command pulse after
passing through the Electronic gear and Position command smoothing.
✔
Position command pulse frequency monitor 1, 2 will be generated in pulse-state
when the position command pulse is 10kHz or less.
When converting it to position command frequency, use it after averaging.
◆
The following low-pass filters are placed into torque monitor, acceleration monitor, and
load torque monitor:
Torque monitor 250Hz
Acceleration monitor 250Hz
Load torque monitor 20Hz