5.Operation
Group 8 control system settings
5-59
ID
Contents
45
Speed Matching Unit Selection
[VCMPUS]
Setting range
Unit
Standard value
00 to 01
-
00_
■
Selects Speed Matching Unit setting method.
Selection
Contents
00
min
-1
Sets by unit[min
-1
]
Uses the setting value of ID46 [VCMP] Speed Matching Range
01
Percent
Sets the ratio to velocity command by [%] unit
Uses the setting value of ID47 [VCMPR] Speed Matching Range
Ratio
46
Speed Matching Range
[VCMP]
Setting range
Unit
Standard value
0.0 to 6553.5
min
-1
5.0
■
Sets the range regarded as Speed matching by the unit [min
-1
].
◆
Use this setting value when ID45 [VCMPUS] Speed Matching Unit Selection is
”
00
min
-1
.
”
◆
Velocity matching is output when the Velocity deviation (difference between the velocity
command and actual velocity) is within this setting range.
47
Speed Matching Range Ratio
[VCMPR]
Setting range
Unit
Standard value
0.0 to 100.0
%
5.0
■
Sets the range regarded as Speed matching ratio to Velocity command by the unit [%].
◆
This setting is used when ID45
”
[VCMPUS] Speed Matching Unit Selection
”
is
“
01 Percent
”
◆
Speed matching is outputted when a velocity deviation (difference of commanded
velocity and real one) is in this setting range.
◆
The value that multiplied the velocity command by setting is a Speed matching range.
When this value is less than 1[min
-1
], the Speed matching range is treated as 1[min
-1
].
Velocity command
Velocity
Within the Speed Matching Range, VCMP_ON or
VCMP_OFF is output from Group9 OUT.
Velocity command
Velocity
Within the Speed Matching Range, VCMP_ON or
VCMP_OFF is output from Group9 OUT.
Содержание M-EGA-15A2301
Страница 149: ...No Text on This Page ...
Страница 237: ......