NV-DVR900 / NV-DVR1600 ver. 2.0 - User’s Manual
All rights reserved © NOVUS Security Sp. z o.o.
22
MULTIPLEXER MENU
3.1.3 PTZ Settings
When this sub-menu is entered a configuration window will be displayed on the screen applying to the
telemetry protocols. In order to ensure proper device operation with Speed Dome Cameras this settings
should confirm to settings preset in cameras. If there are no Speed Dome Cameras in the system then
there is no need for this sub-menu modification.
•
The menu
Model
is used to select Speed Dome Cameras telemetry protocol.
•
The menu
Baud Rate
is used to select transmission speed.
•
The menu
Select Terminal
is used to select telemetry port to which PTZ commands will
be transmitted. Port RS-422 has a output type RJ-45, Port RS-485 is equipped with screw
connectors terminal. PTZ control should be connected to connected to port RS-485.
•
Delete
button is used to delete selected protocol from the list. When this operation is accepted
given protocol will not be longer available on this device.
•
Add
button is used to input new telemetry protocol through USB port or network connection.
In order to familiarize yourself with the details of this operation as well as with available
protocols please contact .